$255.00
X200-022NFU
[XVT2-30]

Input:
240VAC, Single Phase
240VAC, Three Phase
Output:
3 HP, 240VAC, 3Ø
2.2kW, 4.5kVA, 10.0A"
1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

3

2.2

Motor (kW)

2.2

2.3

Capacity (kVA)

4.5

2.4

Output Current (Amps)

10

3.0

Rated Input

3.1

Input Voltage

200 - 240VAC ±10%

3.2

Phase

1 or 3

3.3

Frequency

50/60 ±5%

4.0

Rated Output

4.1

Voltage

200 - 240VAC ±10%

4.2

Phase

3

4.3

Frequency

0.5 - 400 Hz

5.0

Control Method

Line-to-line sine-wave pulse-width (PWM) control

6.0

Frequency Range

0.5 - 400 Hz

7.0

Frequency Accuracy

7.1

Digital Command

0.01% of the max. frequency

7.2

Analog Command

0.4% of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.1 Hz

8.2

Analog

Max. Freq./100

9.0

Volt./Freq. Characteristics

Setting available for constant torque, reduced torque

10.0

Overload Current Rating

150%, 60 seconds

11.0

Acceleration/Deceleration Time

0.1 ~ 3000 sec. (linear/curve, accel./decel.) Second stage accel./decel. setting available

12.0

Braking

12.1

Dynamic Braking

Approx. 100%

12.2

DC Braking

Operating frequency, time and braking force variable

13.0

Input Signal

13.1

Frequency Setting

13.1.1

Digital Operator Panel

Up(1) and Down(2) keys/value setting keys

13.1.2

Potentiometer

Analog Setting

13.1.3

External Signal

0 ~ 10 VDC (input impedence 10k ohms),  4 ~ 20 mA (input impedence 250k ohms) Potentiometer: 1k to 2k ohms, variable resistor The frequency command is the maximum frequency at 9.8V for input voltage 0 - 10 VDC, or at 19.6 mA for input current 4 ~ 20 mA. If this characteristic is not convenient contact Drives Warehouse.

13.2

Forward/Reverse/Start/Stop

13.2.1

Digital Operator Panel

Run/Stop (Forward/Reverse run change by command)

13.2.2

External Signal

Forward RUN/STOP (1a contact)

13.3

Intelligent Input Terminals

FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection).

14.0

Output Signal

14.1

Intelligent Output Terminal

RUN (running signal), FA1,2 (frequency arrival signal),  OL (overload advance notice signal),  OD (deviation signal at PID control), AL (alarm signal)

14.2

Frequency Monitor

PWM output: Select analog output frequency monitor,  analog output current monitor or digital output frequency monitor

15.0

Other Functions

AVR function, upper/lower limiter, PID control, carrier frequency change, frequency jump, electronic thermal level adjustment, gain/bias setting function, retry function

16.0

Protective Function

Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error.

17.0

Environmental Conditions

17.1

Operating Temp.

-10 ~ 50ºC

17.2

Storage Temp.

-10 ~ 70ºC

17.3

Humidity

20 ~ 90 % RH (no condensation)

17.4

Vibration

5.9 m/s² (0.6G), 10 ~ 55 Hz

17.5

Location

Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)

18.0

Mechanical Properties

18.1

Color

Blue

18.2

Height

7.4 inches (189mm)

18.3

Width

4.3 inches (110mm)

18.4

Depth

6.3 inches (159mm)

18.5

Weight (lbs)

9

19.0

Options

Remote operator unit Copy unit Dynamic braking unit Braking resistor AC reactor DC reactor Noise filter

 
X200-022NFU manufacturer: HITACHI - Japan
 
This product was added to our catalog on Thursday 18 September, 2008.
X200-022NFU
Quantity: 
X200-022NFU