$225.00 X200-004HFU
[XVT2-051]

"Input:
460VAC, Three Phase
Output:
1/2 HP, 460VAC, 3Ø
0.4kW, 1.1kVA, 1.5A"""
1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

0.5

2.2

Motor (kW)

0.4

2.3

Capacity (kVA)

1.1

2.4

Output Current (Amps)

1.5

3.0

Rated Input

3.1

Input Voltage

380 - 460VAC ±10%

3.2

Phase

3

3.3

Frequency

50/60 ±5%

4.0

Rated Output

4.1

Voltage

380 - 460VAC ±10%

4.2

Phase

3

4.3

Frequency

0.5 - 400 Hz

5.0

Control Method

Line-to-line sine-wave pulse-width (PWM) control

6.0

Frequency Range

0.5 - 400 Hz

7.0

Frequency Accuracy

7.1

Digital Command

± 0.01% of the max. frequency

7.2

Analog Command

± 0.4% of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.1 Hz

8.2

Analog

Max. Freq./100

9.0

Volt./Freq. Characteristics

"Setting available for constant torque, reduced torque"

10.0

Overload Current Rating

"150%, 60 seconds"

11.0

Acceleration/Deceleration Time

"0.1 ~ 3000 sec. (linear/curve, accel./decel.) Second stage accel./decel. setting available"

12.0

Braking

12.1

Dynamic Braking

Approx. 100%

12.2

DC Braking

"Operating frequency, time and braking force variable"

13.0

Input Signal

13.1

Frequency Setting

13.1.1

Digital Operator Panel

Up(1) and Down(2) keys/value setting keys

13.1.2

Potentiometer

Analog Setting

13.1.3

External Signal

"0 ~ 10 VDC (input impedence 10k ohms),  4 ~ 20 mA (input impedence 250k ohms) Potentiometer: 1k to 2k ohms, variable resistor The frequency command is the maximum frequency at 9.8V for input voltage 0 - 10 VDC, or at 19.6 mA for input current 4 ~ 20 mA. If this characteristic is not convenient contact Drives Warehouse."

13.2

Forward/Reverse/Start/Stop

13.2.1

Digital Operator Panel

Run/Stop (Forward/Reverse run change by command)

13.2.2

External Signal

Forward RUN/STOP (1a contact)

13.3

Intelligent Input Terminals

"FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection)."

14.0

Output Signal

14.1

Intelligent Output Terminal

"RUN (running signal), FA1,2 (frequency arrival signal),  OL (overload advance notice signal),  OD (deviation signal at PID control), AL (alarm signal)"

14.2

Frequency Monitor

"PWM output: Select analog output frequency monitor,  analog output current monitor or digital output frequency monitor"

15.0

Other Functions

"AVR function, upper/lower limiter, PID control, carrier frequency change, frequency jump, electronic thermal level adjustment, gain/bias setting function, retry function"

16.0

Protective Function

"Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error."

17.0

Environmental Conditions

17.1

Operating Temp.

-10 ~ 50ºC

17.2

Storage Temp.

-10 ~ 70ºC

17.3

Humidity

20 ~ 90 % RH (no condensation)

17.4

Vibration

"5.9 m/s² (0.6G), 10 ~ 55 Hz"

17.5

Location

"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"

18.0

Mechanical Properties

18.1

Color

Blue

18.2

Height

7.4 inches (189mm)

18.3

Width

4.3 inches (110mm)

18.4

Depth

5.2 inches (132mm)

18.5

Weight (lbs)

7.9

19.0

Options

Remote operator unit Copy unit Dynamic braking unit Braking resistor AC reactor DC reactor Noise filter

 
X200-004HFU manufacturer: HITACHI - Japan
 