$4,856.00
L300P-900HFU2
[XLT6-1251]

Input:
460VAC, 3 Phase, 176A
Output:
125HP, 460VAC, 3 Phase
90kW, 133kVA, 160A
1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

125

2.2

Motor (kW)

90

2.3

Capacity (kVA)

133

2.4

Output Current (Amps)

160

3.0

Rated Input

3.1

Input Voltage

380 - 480VAC ±10%

3.2

Phase

3

3.3

Frequency

50/60 ±5%

4.0

Rated Output

4.1

Voltage

380 - 480VAC ±10%

4.2

Phase

3

4.3

Frequency

0.1 - 400 Hz

5.0

Control Method

Line to line sine-wave pulse width modulation (PWM) control

6.0

Frequency Range

0.1 - 400 Hz

7.0

Frequency Accuracy

7.1

Digital Command

0.01% of the max. frequency

7.2

Analog Command

0.2% (25ºC ±10ºC) of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.01 Hz

8.2

Analog

Max. frequency/4000

9.0

Volt./Freq. Characteristics

V/F optionally variable, constant torque,  and reduced torque of V/F control.

10.0

Overload Current Rating

120%, 30 Seconds 150%, 0.5 Seconds

11.0

Acceleration/Deceleration Time

0.1 - 3600 sec. (linear/curve, accel./decel.),  Two stage accel./decel. setting available

12.0

Braking

12.1

Dynamic Braking

Built-in BRD circuit (Optional resistor) for 15, 20 HP only. External dynamic braking unit (option) for 25 HP & above. Braking resistor is not integrated in the inverter. Please install optional braking resistor or dynamic braking unit when large control torque is required.

12.2

DC Braking

Performs at start; under set frequency at deceleration, or via an external input (braking force, time and operating frequency)

13.0

Input Signal

13.1

Frequency Setting

13.1.1

Digital Operator Panel

Up(1) and Down(2) keys/value setting keys.

13.1.2

Potentiometer

Set by potentiometer

13.1.3

External Signal

DC 0 ~ 10 VDC,  -10V to +10V (input impedence 10k ohms),  4 ~ 20 mA (input impedence 100k ohms)

13.1.4

External Port

Set by RS485

13.2

Forward/Reverse/Start/Stop

13.2.1

Digital Operator Panel

Run key/Stop key (FW/RV can be set by command)

13.2.2

External Signal

FW RUN/STOP (NO contact), RV set by terminal assignment (NO/NC selection), 3-wire input possible

13.2.3

External Port

Set by RS485

13.3

Intelligent Input Terminals

Selection of 5 functions from: RV (Reverse), CFI~CF4 (Multispeed command), JG (Jogging), DB (External DC braking),  SET (Second motor constants setting), , 2CH (Second accel./decel.) FRS (Free-run stop), EXT (External trip), USP (Unattended Start Protection),  CS (Change to/from commercial power supply) SFT (Software lock), AT (Analog input selection), RS (Reset), STA (3-wire start), STP (3-wire stop), F/R (3-wire fwd./rev.), PID (PID On/Off), PIDC (PID reset), UP/DWN (Remote-controlled accel.decel.), UDC (Remote-controlled data clearing), SF1-SF7 (Multispeed bit command 1-7), OLR (Overload limit change), and NO (Not selected)

13.4

Thermistor Input

One terminal

14.0

Output Signal

14.1

Intelligent Output Terminal

Two NO contacts and one NO-NC combined contact (Selection from: RUN, FA1, FA2, OL, OD, AL, FA3, IP, UV, RNT, ONT and THM)

15.0

Display Monitor

Output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, input power, output voltage.

16.0

Other Functions

V/F free setting (up to 5 points), frequency upper/lower limit, frequency jump,  accel/decel curve selection, manual torque boost value and frequency adjustment,  analog meter tuning, start frequency setting, carrier frequency setting, electronic  thermal free-setting, external frequency output zero/span reference, external frequency  input bias start/end, alalog input selection, retry after trip, restart after instantaneous  power failure, various signal outputs, reduced voltage start, overload restriction,  automatic energy saving.

17.0

Protective Function

Over-current protection, overload protection, braking resistor overload protection,  over-voltage protection, EEPROM error, under-voltage error, CT(Current transformer)  error, CPU error, external trip USP error, ground fault, input over-voltage protection,  instantaneous power failure, option 1 connection error, option 2 connection error,  inverter thermal trip, phase failure detection, IGBT error, thermistor error

18.0

Environmental Conditions

18.1

Operating Temp.

-10 ~ 50ºC

18.2

Storage Temp.

-20 ~ 65ºC

18.3

Humidity

25 ~ 90 % RH(no condensation)

18.4

Vibration

5.9 m/s^2 (0.6G), 10 ~ 55 Hz

18.5

Location

Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)

19.0

Mechanical Properties

19.1

Color

Blue

19.2

Height

27.6 inches (700 mm)

19.3

Width

15.4 inches (390 mm)

19.4

Depth

10.1 inches (279 mm)

19.5

Weight (lbs)

200

20.0

Options

EMI filters, Input/output reactors, DC reactors, Radio noise filters, Braking resistors, Braking units, LCR filter, Multilingual operator with copy function, Communication cables, Option PCB

 
L300P-900HFU2 manufacturer: HITACHI - Japan
 
This product was added to our catalog on Thursday 18 September, 2008.