L300P-150LFU2
[XLT6-200]
|
$1,125.00
|
|
 |
|
|
|
|
 |
|
1.0
|
Motor/Load Type
|
AC Motor
|
|
2.0
|
Rating
|
|
|
2.1
|
Horsepower
|
20
|
|
2.2
|
Motor
(kW)
|
15
|
|
2.3
|
Capacity
(kVA)
|
24.1
|
|
2.4
|
Output Current
(Amps)
|
58
|
|
3.0
|
Rated Input
|
|
|
3.1
|
Input Voltage
|
200 - 240VAC ±10%
|
|
3.2
|
Phase
|
3
|
|
3.3
|
Frequency
|
50/60 ±5%
|
|
4.0
|
Rated Output
|
|
|
4.1
|
Voltage
|
200 - 240VAC ±10%
|
|
4.2
|
Phase
|
3
|
|
4.3
|
Frequency
|
0.1 - 400 Hz
|
|
5.0
|
Control Method
|
Line to line sine-wave pulse width modulation (PWM) control
|
|
6.0
|
Frequency Range
|
0.1 - 400 Hz
|
|
7.0
|
Frequency Accuracy
|
|
|
7.1
|
Digital Command
|
± 0.01% of the max. frequency
|
|
7.2
|
Analog Command
|
± 0.2% (25ºC ±10ºC) of the max. frequency
|
|
8.0
|
Frequency Setting Resolution
|
|
|
8.1
|
Digital
|
0.01 Hz
|
|
8.2
|
Analog
|
Max. frequency/4000
|
|
9.0
|
Volt./Freq. Characteristics
|
"V/F optionally variable, constant torque, and reduced torque of V/F control."
|
|
10.0
|
Overload Current Rating
|
"120%, 30 Seconds 150%, 0.5 Seconds"
|
|
11.0
|
Acceleration/Deceleration Time
|
"0.1 - 3600 sec. (linear/curve, accel./decel.), Two stage accel./decel. setting available"
|
|
12.0
|
Braking
|
|
|
12.1
|
Dynamic Braking
|
"Built-in BRD circuit (Optional resistor) for 15, 20 HP only. External dynamic braking unit (option) for 25 HP & above. Braking resistor is not integrated in the inverter. Please install optional braking resistor or dynamic braking unit when large control torque is required."
|
|
12.2
|
DC Braking
|
"Performs at start; under set frequency at deceleration, or via an external input (braking force, time and operating frequency)"
|
|
13.0
|
Input Signal
|
|
|
13.1
|
Frequency Setting
|
|
|
13.1.1
|
Digital Operator Panel
|
Up(1) and Down(2) keys/value setting keys.
|
|
13.1.2
|
Potentiometer
|
Set by potentiometer
|
|
13.1.3
|
External Signal
|
"DC 0 ~ 10 VDC, -10V to +10V (input impedence 10k ohms), 4 ~ 20 mA (input impedence 100k ohms)"
|
|
13.1.4
|
External Port
|
Set by RS485
|
|
13.2
|
Forward/Reverse/Start/Stop
|
|
|
13.2.1
|
Digital Operator Panel
|
Run key/Stop key (FW/RV can be set by command)
|
|
13.2.2
|
External Signal
|
"FW RUN/STOP (NO contact), RV set by terminal assignment (NO/NC selection), 3-wire input possible"
|
|
13.2.3
|
External Port
|
Set by RS485
|
|
13.3
|
Intelligent Input Terminals
|
"Selection of 5 functions from: RV (Reverse), CFI~CF4 (Multispeed command), JG (Jogging), DB (External DC braking), SET (Second motor constants setting), , 2CH (Second accel./decel.) FRS (Free-run stop), EXT (External trip), USP (Unattended Start Protection), CS (Change to/from commercial power supply) SFT (Software lock), AT (Analog input selection), RS (Reset), STA (3-wire start), STP (3-wire stop), F/R (3-wire fwd./rev.), PID (PID On/Off), PIDC (PID reset), UP/DWN (Remote-controlled accel.decel.), UDC (Remote-controlled data clearing), SF1-SF7 (Multispeed bit command 1-7), OLR (Overload limit change), and NO (Not selected)"
|
|
13.4
|
Thermistor Input
|
One terminal
|
|
14.0
|
Output Signal
|
|
|
14.1
|
Intelligent Output Terminal
|
"Two NO contacts and one NO-NC combined contact (Selection from: RUN, FA1, FA2, OL, OD, AL, FA3, IP, UV, RNT, ONT and THM)"
|
|
15.0
|
Display Monitor
|
"Output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, input power, output voltage."
|
|
16.0
|
Other Functions
|
"V/F free setting (up to 5 points), frequency upper/lower limit, frequency jump, accel/decel curve selection, manual torque boost value and frequency adjustment, analog meter tuning, start frequency setting, carrier frequency setting, electronic thermal free-setting, external frequency output zero/span reference, external frequency input bias start/end, alalog input selection, retry after trip, restart after instantaneous power failure, various signal outputs, reduced voltage start, overload restriction, automatic energy saving."
|
|
17.0
|
Protective Function
|
"Over-current protection, overload protection, braking resistor overload protection, over-voltage protection, EEPROM error, under-voltage error, CT(Current transformer) error, CPU error, external trip USP error, ground fault, input over-voltage protection, instantaneous power failure, option 1 connection error, option 2 connection error, inverter thermal trip, phase failure detection, IGBT error, thermistor error"
|
|
18.0
|
Environmental Conditions
|
|
|
18.1
|
Operating Temp.
|
-10 ~ 50ºC
|
|
18.2
|
Storage Temp.
|
-20 ~ 65ºC
|
|
18.3
|
Humidity
|
25 ~ 90 % RH(no condensation)
|
|
18.4
|
Vibration
|
"5.9 m/s^2 (0.6G), 10 ~ 55 Hz"
|
|
18.5
|
Location
|
"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"
|
|
19.0
|
Mechanical Properties
|
|
|
19.1
|
Color
|
Blue
|
|
19.2
|
Height
|
10.2 inches (260 mm)
|
|
19.3
|
Width
|
8.2 inches (210 mm)
|
|
19.4
|
Depth
|
7.0 inches (178.5 mm)
|
|
19.5
|
Weight
(lbs)
|
11
|
|
20.0
|
Options
|
"EMI filters, Input/output reactors, DC reactors, Radio noise filters, Braking resistors, Braking units, LCR filter, Multilingual operator with copy function, Communication cables, Option PCB"
|
|
|
This product was added to our catalog on Monday 13 November, 2006.
|
 |
|
|
|