Online Source for AC DC Electric Motor Drives DRIVESWAREHOUSE.COM
6770 Twin Hills Avenue
Dallas, TX 75231, U.S.A.

Call 1-888-476-5944  (Lines open 7 Days)
12 Months Warranty
Discounts available on Quantity
 
 Drives   Motors   Panel 
 
  Home » Drives » AC Drives   Brands     Drives      Accessories   My Account  |  Cart Contents  |  Checkout   
    
Drives (308)
AC Drives (133)
Micro VFD (3)
Phase Converter VFD (15)
Variable Torque VFD (52)
Sensorless Vector VFD (21)
Flux Vector Drive (42)
DC Drives (175)
Panel (143)
Motors (660)
Accessories (152)

L300P-150HFU2
[XLT6-201]

 $1,075.00

"Input:
460VAC, 3 Phase, 32A
Output:
20HP, 460VAC, 3 Phase
15kW, 24.1kVA, 29A"

Brochure
Specifications
Reference Guide
Instruction Manual
Printer Friendly Version
Email this Page to a Friend
Click here to view larger image

Click here to view larger image

1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

20

2.2

Motor (kW)

15

2.3

Capacity (kVA)

24.1

2.4

Output Current (Amps)

29

3.0

Rated Input

3.1

Input Voltage

380 - 480VAC ±10%

3.2

Phase

3

3.3

Frequency

50/60 ±5%

4.0

Rated Output

4.1

Voltage

380 - 480VAC ±10%

4.2

Phase

3

4.3

Frequency

0.1 - 400 Hz

5.0

Control Method

Line to line sine-wave pulse width modulation (PWM) control

6.0

Frequency Range

0.1 - 400 Hz

7.0

Frequency Accuracy

7.1

Digital Command

± 0.01% of the max. frequency

7.2

Analog Command

± 0.2% (25ºC ±10ºC) of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.01 Hz

8.2

Analog

Max. frequency/4000

9.0

Volt./Freq. Characteristics

"V/F optionally variable, constant torque,  and reduced torque of V/F control."

10.0

Overload Current Rating

"120%, 30 Seconds 150%, 0.5 Seconds"

11.0

Acceleration/Deceleration Time

"0.1 - 3600 sec. (linear/curve, accel./decel.),  Two stage accel./decel. setting available"

12.0

Braking

12.1

Dynamic Braking

"Built-in BRD circuit (Optional resistor) for 15, 20 HP only. External dynamic braking unit (option) for 25 HP & above. Braking resistor is not integrated in the inverter. Please install optional braking resistor or dynamic braking unit when large control torque is required."

12.2

DC Braking

"Performs at start; under set frequency at deceleration, or via an external input (braking force, time and operating frequency)"

13.0

Input Signal

13.1

Frequency Setting

13.1.1

Digital Operator Panel

Up(1) and Down(2) keys/value setting keys.

13.1.2

Potentiometer

Set by potentiometer

13.1.3

External Signal

"DC 0 ~ 10 VDC,  -10V to +10V (input impedence 10k ohms),  4 ~ 20 mA (input impedence 100k ohms)"

13.1.4

External Port

Set by RS485

13.2

Forward/Reverse/Start/Stop

13.2.1

Digital Operator Panel

Run key/Stop key (FW/RV can be set by command)

13.2.2

External Signal

"FW RUN/STOP (NO contact), RV set by terminal assignment (NO/NC selection), 3-wire input possible"

13.2.3

External Port

Set by RS485

13.3

Intelligent Input Terminals

"Selection of 5 functions from: RV (Reverse), CFI~CF4 (Multispeed command), JG (Jogging), DB (External DC braking),  SET (Second motor constants setting), , 2CH (Second accel./decel.) FRS (Free-run stop), EXT (External trip), USP (Unattended Start Protection),  CS (Change to/from commercial power supply) SFT (Software lock), AT (Analog input selection), RS (Reset), STA (3-wire start), STP (3-wire stop), F/R (3-wire fwd./rev.), PID (PID On/Off), PIDC (PID reset), UP/DWN (Remote-controlled accel.decel.), UDC (Remote-controlled data clearing), SF1-SF7 (Multispeed bit command 1-7), OLR (Overload limit change), and NO (Not selected)"

13.4

Thermistor Input

One terminal

14.0

Output Signal

14.1

Intelligent Output Terminal

"Two NO contacts and one NO-NC combined contact (Selection from: RUN, FA1, FA2, OL, OD, AL, FA3, IP, UV, RNT, ONT and THM)"

15.0

Display Monitor

"Output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, input power, output voltage."

16.0

Other Functions

"V/F free setting (up to 5 points), frequency upper/lower limit, frequency jump,  accel/decel curve selection, manual torque boost value and frequency adjustment,  analog meter tuning, start frequency setting, carrier frequency setting, electronic  thermal free-setting, external frequency output zero/span reference, external frequency  input bias start/end, alalog input selection, retry after trip, restart after instantaneous  power failure, various signal outputs, reduced voltage start, overload restriction,  automatic energy saving."

17.0

Protective Function

"Over-current protection, overload protection, braking resistor overload protection,  over-voltage protection, EEPROM error, under-voltage error, CT(Current transformer)  error, CPU error, external trip USP error, ground fault, input over-voltage protection,  instantaneous power failure, option 1 connection error, option 2 connection error,  inverter thermal trip, phase failure detection, IGBT error, thermistor error"

18.0

Environmental Conditions

18.1

Operating Temp.

-10 ~ 50ºC

18.2

Storage Temp.

-20 ~ 65ºC

18.3

Humidity

25 ~ 90 % RH(no condensation)

18.4

Vibration

"5.9 m/s^2 (0.6G), 10 ~ 55 Hz"

18.5

Location

"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"

19.0

Mechanical Properties

19.1

Color

Blue

19.2

Height

10.2 inches (260 mm)

19.3

Width

8.2 inches (210 mm)

19.4

Depth

7.0 inches (178.5 mm)

19.5

Weight (lbs)

11

20.0

Options

"EMI filters, Input/output reactors, DC reactors, Radio noise filters, Braking resistors, Braking units, LCR filter, Multilingual operator with copy function, Communication cables, Option PCB"

This product was added to our catalog on Monday 13 November, 2006.
Reviews Printer Friendly Add to Cart
Customers who bought this product also purchased
ICS-3
L200-007NFU
L200-022HFU
 
 
driveswarehouse.com    HACKER  SAFE certified sites prevent over 99.9% of hacker crime.       Click to verify BBB accreditation and to see a BBB report.
If you need help in Finding a suitable drive: Click here

If you know the Drive Model Number Enter here:
 

Otherwise use
Advanced Search to narrow your search
Micro VFD
Phase Converter VFD
Variable Torque VFD
Sensorless Vector VFD
Flux Vector Drive
Regen.(D), 3 Phase
Non-Regen.(D), 3 Phase
Non-Regen.(A), 1 Phase
Non-Regen.(A), 3 Phase
Regen.(A), 1 Phase
Regen.(A), 3 Phase
 
Tell someone you know about this product.
Notifications Notify me of updates to L300P-150HFU2
HITACHI - Japan Homepage
Other products
FAQ
Reviews
News/Press Releases
Reward Program
Conditions of Use
Contact Us
User Guide
 
 

All content copyright Drives Warehouse