L200-040HFU
[XLT7-51]
|
$350.00
|
|
 |
|
|
|
|
 |
|
1.0
|
Motor/Load Type
|
AC Motor
|
|
2.0
|
Rating
|
|
|
2.1
|
Horsepower
|
5
|
|
2.2
|
Motor
(kW)
|
4
|
|
2.3
|
Capacity
(kVA)
|
6.8
|
|
2.4
|
Output Current
(Amps)
|
8.6
|
|
3.0
|
Rated Input
|
|
|
3.1
|
Input Voltage
|
380 - 460VAC ±10%
|
|
3.2
|
Phase
|
3
|
|
3.3
|
Frequency
|
50/60 ±5%
|
|
4.0
|
Rated Output
|
|
|
4.1
|
Voltage
|
380 - 460VAC ±10%
|
|
4.2
|
Phase
|
3
|
|
4.3
|
Frequency
|
0.5 - 360 Hz
|
|
5.0
|
Control Method
|
Sine-Wave (PWM) control
|
|
6.0
|
Frequency Range
|
0.5 - 360 Hz
|
|
7.0
|
Frequency Accuracy
|
|
|
7.1
|
Digital Command
|
± 0.01% of the max. frequency
|
|
7.2
|
Analog Command
|
± 0.2% of the max. frequency
|
|
8.0
|
Frequency Setting Resolution
|
|
|
8.1
|
Digital
|
0.1 Hz
|
|
8.2
|
Analog
|
Max. Freq./100
|
|
9.0
|
Volt./Freq. Characteristics
|
"Setting available for constant torque, reduced torque"
|
|
10.0
|
Overload Current Rating
|
"150%, 60 seconds"
|
|
11.0
|
Acceleration/Deceleration Time
|
"0.1 ~ 3000 sec. (linear/curve, accel./decel.) Second stage accel./decel. setting available"
|
|
12.0
|
Braking
|
|
|
12.1
|
Dynamic Braking
|
Approx. 20%
|
|
12.2
|
DC Braking
|
"Operating frequency, time and braking force variable"
|
|
13.0
|
Input Signal
|
|
|
13.1
|
Frequency Setting
|
|
|
13.1.1
|
Digital Operator Panel
|
Up(1) and Down(2) keys/value setting keys
|
|
13.1.2
|
Potentiometer
|
Analog Setting
|
|
13.1.3
|
External Signal
|
"0 ~ 10 VDC (input impedence 10k ohms), 4 ~ 20 mA (input impedence 250k ohms) Potentiometer: 1k to 2k ohms, variable resistor The frequency command is the maximum frequency at 9.8V for input voltage 0 - 10 VDC, or at 19.6 mA for input current 4 ~ 20 mA. If this characteristic is not convenient contact Drives Warehouse."
|
|
13.2
|
Forward/Reverse/Start/Stop
|
|
|
13.2.1
|
Digital Operator Panel
|
Run/Stop (Forward/Reverse run change by command)
|
|
13.2.2
|
External Signal
|
Forward RUN/STOP (1a contact)
|
|
13.3
|
Intelligent Input Terminals
|
"FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection)."
|
|
14.0
|
Output Signal
|
|
|
14.1
|
Intelligent Output Terminal
|
"RUN (running signal), FA1,2 (frequency arrival signal), OL (overload advance notice signal), OD (deviation signal at PID control), AL (alarm signal)"
|
|
14.2
|
Frequency Monitor
|
"PWM output: Select analog output frequency monitor, analog output current monitor or digital output frequency monitor"
|
|
15.0
|
Other Functions
|
"AVR function, upper/lower limiter, PID control, carrier frequency change, frequency jump, electronic thermal level adjustment, gain/bias setting function, retry function"
|
|
16.0
|
Protective Function
|
"Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error."
|
|
17.0
|
Environmental Conditions
|
|
|
17.1
|
Operating Temp.
|
-10 ~ 50ºC
|
|
17.2
|
Storage Temp.
|
-10 ~ 70ºC
|
|
17.3
|
Humidity
|
20 ~ 90 % RH (no condensation)
|
|
17.4
|
Vibration
|
"5.9 m/s² (0.6G), 10 ~ 55 Hz"
|
|
17.5
|
Location
|
"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"
|
|
18.0
|
Mechanical Properties
|
|
|
18.1
|
Color
|
Blue
|
|
18.2
|
Height
|
7.1 inches (181mm)
|
|
18.3
|
Width
|
5.5 inches (140mm)
|
|
18.4
|
Depth
|
6.7 inches (171mm)
|
|
18.5
|
Weight
(lbs)
|
11.2
|
|
19.0
|
Options
|
Remote operator unit Copy unit Dynamic braking unit Braking resistor AC reactor DC reactor Noise filter
|
|
|
This product was added to our catalog on Monday 13 November, 2006.
|
 |
|
|
|

| Customers who bought this product also purchased |
|
|
|
|
 |
|
|
|
|
|
|
 |
|