SV022iC5-1
[SV022iC5-1]
|
$299.00
|
|
 |
|
|
|
|
 |
|
1.0
|
Motor/Load Type
|
AC Motor
|
|
2.0
|
Rating
|
|
|
2.1
|
Horsepower
|
3
|
|
2.2
|
Motor
(kW)
|
2.2
|
|
2.3
|
Capacity
(kVA)
|
4.5
|
|
2.4
|
Output Current
(Amps)
|
12
|
|
3.0
|
Rated Input
|
|
|
3.1
|
Input Voltage
|
200 - 230VAC ±10%
|
|
3.2
|
Phase
|
Single OR Three
|
|
3.3
|
Frequency
|
50 ~ 60 ±5%
|
|
4.0
|
Rated Output
|
|
|
4.1
|
Voltage
|
200 - 230VAC ±10%
|
|
4.2
|
Phase
|
Three
|
|
4.3
|
Frequency
|
0.1 ~ 400 Hz
|
|
5.0
|
Control Method
|
V/F & Sensorless Vector (PWM)
|
|
6.0
|
Frequency Range
|
0.1 ~ 400 Hz
|
|
7.0
|
Frequency Accuracy
|
|
|
7.1
|
Digital Command
|
± 0.01% of the max. frequency
|
|
7.2
|
Analog Command
|
± 0.1% of the max. frequency
|
|
8.0
|
Frequency Setting Resolution
|
|
|
8.1
|
Digital
|
0.01 Hz
|
|
8.2
|
Analog
|
0.06Hz / 60Hz
|
|
9.0
|
Volt./Freq. Characteristics
|
"Linear, Square pattern, User V/F"
|
|
10.0
|
Overload Current Rating
|
"1 min. at 150%, 30sec at 200% (with reverse characteristics)"
|
|
11.0
|
Acceleration/Deceleration Time
|
"0.1 ~ 6000 sec. max 8 types available by Multi-function terminal, selectable accel./decel. patterns: linear, U and S."
|
|
12.0
|
Starting Torque
|
0~150% adjustable
|
|
13.0
|
Braking
|
|
|
13.1
|
Dynamic Braking
|
Approx. 100%
|
|
13.2
|
DC Braking
|
"Operating frequency, time and braking force variable"
|
|
14.0
|
Input Signal
|
|
|
14.1
|
Frequency Setting
|
|
|
14.1.1
|
Digital Operator Panel
|
Keypad
|
|
14.1.2
|
Potentiometer
|
Manual
|
|
14.1.3
|
External Signal
|
0 ~ 10 VDC 4 ~ 20 mA
|
|
14.2
|
Forward/Reverse/Start/Stop
|
|
|
14.2.1
|
Digital Operator Panel
|
Forward / Reverse
|
|
15.0
|
Output Signal
|
|
|
15.1
|
Frequency Monitor
|
"Frequency detection, Overload alarm, Stalling, Overvoltage and Undervoltage."
|
|
16.0
|
Display Monitor
|
"Drive overheating, Run, Stop, Constant Speed, Speed searching, Fault output (Relay and Open collector output)"
|
|
17.0
|
Other Functions
|
"DC Braking, Frequency limit, Frequency jump, Second function, Slip compensation, Reversing prevention, Auto restart, PID control."
|
|
18.0
|
Protective Function
|
"Overvoltage, Undervoltage, Overcurrent, Drive overtemperature, Motor overtemperature, I/O phase loss, I/O mis-wiring, Overload, External device fault, loss of speed command, hardware fault, communication error, CPU error."
|
|
19.0
|
Environmental Conditions
|
|
|
19.1
|
Operating Temp.
|
-10 ~ 40ºC
|
|
19.2
|
Storage Temp.
|
-20 ~ 65ºC
|
|
19.3
|
Humidity
|
90 % RH (no condensation)
|
|
19.4
|
Vibration
|
"5.9 m/s² (0.6G), 10 ~ 55 Hz"
|
|
19.5
|
Location
|
"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"
|
|
20.0
|
Mechanical Properties
|
|
|
20.1
|
Color
|
Neutral
|
|
20.2
|
Height
|
5.6 inches (143mm)
|
|
20.3
|
Width
|
6.1 inches (156mm)
|
|
20.4
|
Depth
|
5.6 inches (143mm)
|
|
20.5
|
Weight
(lbs)
|
9.2
|
|
21.0
|
Options
|
Modbus Communication Windows based monitoring Software
|
|
|
This product was added to our catalog on Monday 13 November, 2006.
|
 |
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
 |
|