$720.00 SJ200-075LFU
[PSV6-100]

"Input:
230VAC, Three Phase
Output:
10 HP, 230VAC, Three Phase
7.5kW, 12.2kVA, 32A"
1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

10

2.2

Motor (kW)

7.5

2.3

Capacity (kVA)

12.2

2.4

Output Current (Amps)

32

3.0

Rated Input

3.1

Input Voltage

200 - 240VAC ±10%

3.2

Phase

3

3.3

Frequency

50/60 ±5%

4.0

Rated Output

4.1

Voltage

200 - 240VAC ±10%

4.2

Phase

3

4.3

Frequency

0.1 - 400 Hz

5.0

Control Method

Line-to-line sine wave Pulse Width Modulation (PWM) Control

6.0

Frequency Range

0.1 - 400 Hz

7.0

Frequency Accuracy

7.1

Digital Command

±0.1% of the max. frequency

7.2

Analog Command

±0.2% of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.01 Hz

8.2

Analog

Max. frequency/1000

9.0

Volt./Freq. Characteristics

"V/F variable V/F control (constant torque, reduced torque) Sensorless vector control"

10.0

Overload Current Rating

"150%, 60 Seconds"

11.0

Acceleration/Deceleration Time

"0.1 - 3000 sec. (linear/curve, accel./decel.),  Two stage accel./decel. setting available"

12.0

Starting Torque

200% or more

13.0

Braking

13.1

Dynamic Braking

"Dynamic Braking (without external resister) -  Approx. 100% - up to 1 HP Dynamic Braking (with external resister) -  Approx. 150% The braking torque at capacitive feedback is the average deceleration torque at the shortest deceleration (stoppage from 50 Hz) of the motor itself. It is not the continuous regenerative braking torque. And the average deceleration torque varies with motor loss. This value decreases when operating beyond 50/60 Hz. If a large regeneration torque is required, the optional braking resistor should be used."

13.2

DC Braking

"Operating frequency, time and braking force variable."

14.0

Input Signal

14.1

Frequency Setting

14.1.1

Digital Operator Panel

Up(1) and Down(2) keys/value setting keys.

14.1.2

Potentiometer

Analog Setting

14.1.3

External Signal

"0 ~ 10 VDC (input impedence 10k ohms),  4 ~ 20 mA (input impedence 250k ohms) Potentiometer: 1k to 2k ohms, variable resistor The frequency command is the maximum frequency at 9.8V for input voltage 0 - 10 VDC, or at 19.6 mA for input current 4 ~ 20 mA. If this characteristic is not convenient,  contact Drives Warehouse."

14.2

Forward/Reverse/Start/Stop

14.2.1

Digital Operator Panel

Run/Stop (Forward/Reverse run change by command)

14.2.2

External Signal

"Forward RUN/STOP, Reverse RUN/STOP"

14.3

Intelligent Input Terminals

"FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection), DB (external DC braking command, SET (2nd setting selection), UP (remote control, acceleration), DWN (remote control, deceleration)"

15.0

Output Signal

15.1

Intelligent Output Terminal

"RUN (running signal), FA1,2 (frequency arrival signal), OL (overload advance notice signal),  OD (deviation signal at PID control), AL (alarm signal)"

15.2

Frequency Monitor

"PWM output: Select analog output frequency monitor,  analog output current monitor or digital output frequency monitor"

16.0

Other Functions

"AVR function, curved acceleration/deceleration, upper/lower limiter, 16-stage speed, fine adjustment of start frequency, carrier frequency change (0.5 to 10 Kz) frequency jump, gain and bias setting, process incing, electronic thermal level adjustment, retry function history monitor, 2nd setting selection, auto tuning, Fan on/off selection PID control, carrier frequency change, frequency jump."

17.0

Protective Function

"Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error, Electronic thermal, CT error"

18.0

Environmental Conditions

18.1

Operating Temp.

-10 ~ 50ºC

18.2

Storage Temp.

-20 ~ 70ºC

18.3

Humidity

25 ~ 90 % RH (no condensation)

18.4

Vibration

"5.9 m/s² (0.6G), 10 ~ 55 Hz"

18.5

Location

Less than 1000 m of altitude or less

19.0

Mechanical Properties

19.1

Color

Munsell 8.5YR6.2/0.2

19.2

Height

8.6 inches (220 mm)

19.3

Width

7.1 inches (180 mm)

19.4

Depth

6.1 inches (155 mm)

19.5

Weight (lbs)

12

20.0

Options

"Remote operator unit, Copy unit, Cables for the units, Dynamic braking unit, Braking resistor, AC reactor, DC reactor, Noise filter"

This product was added to our catalog on Thursday 18 September, 2008.