| 1.0 |
Motor/Load Type |
AC Motor |
| 2.0 |
Rating |
|
| 2.1 |
Horsepower |
0.5 |
| 2.2 |
Motor (kW) |
0.4 |
| 2.3 |
Capacity (kVA) |
1 |
| 2.4 |
Output Current (Amps) |
2.6 |
| 3.0 |
Rated Input |
|
| 3.1 |
Input Voltage |
200 - 230VAC ±10% |
| 3.2 |
Phase |
1 |
| 3.3 |
Frequency |
50/60 ±5% |
| 4.0 |
Rated Output |
|
| 4.1 |
Voltage |
200 - 240VAC ±10% |
| 4.2 |
Phase |
3 |
| 4.3 |
Frequency |
0.5 - 400 Hz |
| 5.0 |
Control Method |
Line-to-line sine-wave pulse-width (PWM) control |
| 6.0 |
Frequency Range |
0.5 - 400 Hz |
| 7.0 |
Frequency Accuracy |
|
| 7.1 |
Digital Command |
± 0.01% of the max. frequency |
| 7.2 |
Analog Command |
± 0.4% of the max. frequency |
| 8.0 |
Frequency Setting Resolution |
|
| 8.1 |
Digital |
0.1 Hz |
| 8.2 |
Analog |
Max. Freq./100 |
| 9.0 |
Volt./Freq. Characteristics |
"Setting available for constant torque, reduced torque" |
| 10.0 |
Overload Current Rating |
"150%, 60 seconds" |
| 11.0 |
Acceleration/Deceleration Time |
"0.1 ~ 3000 sec. (linear/curve, accel./decel.) Second stage accel./decel. setting available" |
| 12.0 |
Braking |
|
| 12.1 |
DC Braking |
Approx. 100% |
| 13.0 |
Input Signal |
"Operating frequency, time and braking force variable" |
| 13.1 |
Frequency Setting |
|
| 13.1.1 |
Potentiometer |
Up(1) and Down(2) keys/value setting keys |
| 13.1.2 |
External Signal |
Analog Setting |
| 13.2 |
Forward/Reverse/Start/Stop |
"0 ~ 10 VDC (input impedence 10k ohms), 4 ~ 20 mA (input impedence 250k ohms) Potentiometer: 1k to 2k ohms, variable resistor The frequency command is the maximum frequency at 9.8V for input voltage 0 - 10 VDC, or at 19.6 mA for input current 4 ~ 20 mA. If this characteristic is not convenient contact Drives Warehouse." |
| 13.3 |
Intelligent Input Terminals |
Run/Stop (Forward/Reverse run change by command) |
| 14.0 |
Output Signal |
Forward RUN/STOP (1a contact) |
| 14.1 |
Frequency Monitor |
"FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection)." |
| 15.0 |
Environmental Conditions |
"RUN (running signal), FA1,2 (frequency arrival signal), OL (overload advance notice signal), OD (deviation signal at PID control), AL (alarm signal)" |
| 15.1 |
Operating Temp. |
"PWM output: Select analog output frequency monitor, analog output current monitor or digital output frequency monitor" |
| 15.2 |
Humidity |
"AVR function, upper/lower limiter, PID control, carrier frequency change, frequency jump, electronic thermal level adjustment, gain/bias setting function, retry function" |
| 15.3 |
Vibration |
"Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error." |
| 16.0 |
Mechanical Properties |
-10 ~ 50ºC |
| 16.1 |
Color |
-10 ~ 70ºC |
| 16.2 |
Height |
20 ~ 90 % RH (no condensation) |
| 16.3 |
Width |
"5.9 m/s² (0.6G), 10 ~ 55 Hz" |
| 16.4 |
Depth |
"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)" |
| 17.0 |
Options |
Blue |