$140.00 X200-002NFU1
[XVT2-03-1]

"Input:
240VAC, Single Phase
240VAC, Three Phase
Output:
1/4 HP, 240VAC, 3Ø
0.2kW, 0.5kVA, 1.4A"""
1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

0.25

2.2

Motor (kW)

0.2

2.3

Capacity (kVA)

0.5

2.4

Output Current (Amps)

1.4

3.0

Rated Input

3.1

Input Voltage

200 - 230VAC ±10%

3.2

Phase

1

3.3

Frequency

50/60 ±5%

4.0

Rated Output

4.1

Voltage

200 - 240VAC ±10%

4.2

Phase

3

4.3

Frequency

0.5 - 400 Hz

5.0

Control Method

Line-to-line sine-wave pulse-width (PWM) control

6.0

Frequency Range

0.5 - 400 Hz

7.0

Frequency Accuracy

7.1

Digital Command

± 0.01% of the max. frequency

7.2

Analog Command

± 0.4% of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.1 Hz

8.2

Analog

Max. Freq./100

9.0

Volt./Freq. Characteristics

"Setting available for constant torque, reduced torque"

10.0

Overload Current Rating

"150%, 60 seconds"

11.0

Acceleration/Deceleration Time

"0.1 ~ 3000 sec. (linear/curve, accel./decel.) Second stage accel./decel. setting available"

12.0

Braking

12.1

DC Braking

Approx. 100%

13.0

Input Signal

"Operating frequency, time and braking force variable"

13.1

Frequency Setting

13.1.1

Potentiometer

Up(1) and Down(2) keys/value setting keys

13.1.2

External Signal

Analog Setting

13.2

Forward/Reverse/Start/Stop

"0 ~ 10 VDC (input impedence 10k ohms),  4 ~ 20 mA (input impedence 250k ohms) Potentiometer: 1k to 2k ohms, variable resistor The frequency command is the maximum frequency at 9.8V for input voltage 0 - 10 VDC, or at 19.6 mA for input current 4 ~ 20 mA. If this characteristic is not convenient contact Drives Warehouse."

13.3

Intelligent Input Terminals

Run/Stop (Forward/Reverse run change by command)

14.0

Output Signal

Forward RUN/STOP (1a contact)

14.1

Frequency Monitor

"FW (Forward run command), RV (reverse run command, CF1~CF4 (multi-stage speed setting), JG (jogging command), 2CH (2-stage acceleration/deceleration command), FRS (free run stop command), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input select signal), RS (reset), PTC (thermal protection)."

15.0

Environmental Conditions

"RUN (running signal), FA1,2 (frequency arrival signal),  OL (overload advance notice signal),  OD (deviation signal at PID control), AL (alarm signal)"

15.1

Operating Temp.

"PWM output: Select analog output frequency monitor,  analog output current monitor or digital output frequency monitor"

15.2

Humidity

"AVR function, upper/lower limiter, PID control, carrier frequency change, frequency jump, electronic thermal level adjustment, gain/bias setting function, retry function"

15.3

Vibration

"Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error."

16.0

Mechanical Properties

-10 ~ 50ºC

16.1

Color

-10 ~ 70ºC

16.2

Height

20 ~ 90 % RH (no condensation)

16.3

Width

"5.9 m/s² (0.6G), 10 ~ 55 Hz"

16.4

Depth

"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"

17.0

Options

Blue

 
X200-002NFU1 manufacturer: HITACHI - Japan
 