1.0
|
Motor/Load Type
|
AC Motor
|
|
2.0
|
Rating
|
|
|
2.1
|
Horsepower
|
7.5
|
|
2.2
|
Motor
(kW)
|
5.5
|
|
2.3
|
Capacity
(kVA)
|
9.4
|
|
2.4
|
Output Current
(Amps)
|
25
|
|
3.0
|
Rated Input
|
|
|
3.1
|
Input Voltage
|
200 - 230VAC ±10%
|
|
3.2
|
Phase
|
1
|
|
3.3
|
Frequency
|
50/60 ±5%
|
|
4.0
|
Rated Output
|
|
|
4.1
|
Voltage
|
200 - 240VAC ±10%
|
|
4.2
|
Phase
|
3
|
|
4.3
|
Frequency
|
0.1 - 600 Hz
|
|
5.0
|
Control Method
|
Sine-Wave (PWM) control
|
|
6.0
|
Frequency Range
|
0.1 - 600 Hz
|
|
7.0
|
Frequency Accuracy
|
|
|
7.1
|
Digital Command
|
± 0.01% of the max. frequency
|
|
7.2
|
Analog Command
|
± 0.2% of the max. frequency
|
|
8.0
|
Frequency Setting Resolution
|
|
|
8.1
|
Digital
|
0.1 Hz
|
|
8.2
|
Analog
|
Max. Freq./100
|
|
9.0
|
Volt./Freq. Characteristics
|
Adjustable V/F curve using 4 independent points.
|
|
10.0
|
Overload Current Rating
|
"150%, 60 seconds"
|
|
11.0
|
Acceleration/Deceleration Time
|
0.1 ~ 6000 sec. (2 independent settings for Accel/Decel Time)
|
|
12.0
|
Braking
|
|
|
12.1
|
DC Braking
|
DC Braking Current Level: 0 to 125% of rated output current. DC Braking time: 0 to 60 seconds. Start-Point for DC Braking: 0.1-600Hz both when start up and stop.
|
|
13.0
|
Input Signal
|
|
|
13.1
|
Frequency Setting
|
|
|
13.1.1
|
Digital Operator Panel
|
By a rotary encoder (setting resolution 0.01Hz/step)
|
|
13.1.2
|
External Signal
|
"0 ~ +10VDC((Input impedance 20k?), -10 ~ +10VDC((Input impedance 10k?),4 ~20mA dc ((Input impedance 250?),Multi-Function Inputs 1 ~ 6 (15 Steps Jog, up/down), PLC run, RS-485 Interface MODBUS protocol "
|
|
13.2
|
Forward/Reverse/Start/Stop
|
|
|
13.2.1
|
Digital Operator Panel
|
"Set by RUN, STOP and JOG"
|
|
14.0
|
Other Functions
|
"PID feedback control, automatic voltage regulation, Momentary Power Loss restart, S-Curve, External Fault, Fault Reset, Auto Restart, Fault Records, Prevention, Frequency Limits,Fan & Pump Control, Parameter Lock/Reset, Auto Tuning, Reverse Inhibition, Over-Voltage/ Over-Current Stall Prevention, automatic energy-saving, DC Braking, Speed Search during Start-up, PLC, MODBUS Communication,"
|
|
15.0
|
Protective Function
|
"Self-testing, AC source Over Voltage, Over Voltage, Over Current, Under Voltage, Over Load, Overheating, External Fault, Electronic thermal, Ground Fault, Stall Prevention, Output short circuit, IGBT short circuit"
|
|
16.0
|
Environmental Conditions
|
|
|
16.1
|
Operating Temp.
|
Ambient: -10? ~ +40?(Non-Condensing and not frozen).Storage: -20? ~ +60?
|
|
16.2
|
Humidity
|
Below 90?RH (Non-Condensing)
|
|
16.3
|
Vibration
|
"Below 20Hz: 1G, above 20Hz: 0.6G"
|
|
16.4
|
Location
|
"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"
|
|
17.0
|
Mechanical Properties
|
|
|
17.1
|
Color
|
Black
|
|
17.2
|
Height
|
18.4 inches (458mm)
|
|
17.3
|
Width
|
10.24 inches (260mm)
|
|
17.4
|
Depth
|
9.5 inches (242mm)
|
|
17.5
|
Weight
(lbs)
|
29.1
|
|
18.0
|
Options
|
Dynamic braking unit Braking resistor AC reactor
|
|
|
This product was added to our catalog on Thursday 23 August, 2007.
|
 |
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
 |
|