$2,325.00
PC1-200
[PC1-200]

Input:
240VAC, Single Phase
Output:
20 HP, 240VAC, Three Phase
15kW, 22.9kVA, 60.0A"
1.0

Motor/Load Type

AC Motor

2.0

Rating

2.1

Horsepower

20

2.2

Motor (kW)

15

2.3

Capacity (kVA)

22.9

2.4

Output Current (Amps)

60

3.0

Rated Input

3.1

Input Voltage

200 - 230VAC

3.2

Phase

1

3.3

Frequency

50/60

4.0

Rated Output

4.1

Voltage

200 - 240VAC

4.2

Phase

3

4.3

Frequency

0.1 - 600 Hz

5.0

Control Method

Sine-Wave (PWM) control

6.0

Frequency Range

0.1 - 600 Hz

7.0

Frequency Accuracy

7.1

Digital Command

0.01% of the max. frequency

7.2

Analog Command

0.2% of the max. frequency

8.0

Frequency Setting Resolution

8.1

Digital

0.1 Hz

8.2

Analog

Max. Freq./100

9.0

Volt./Freq. Characteristics

Adjustable V/F curve using 4 independent points.

10.0

Overload Current Rating

150%, 60 seconds

11.0

Acceleration/Deceleration Time

0.1 ~ 6000 sec. (2 independent settings for Accel/Decel Time)

12.0

Braking

12.1

DC Braking

DC Braking Current Level: 0 to 125% of rated output current. DC Braking time: 0 to 60 seconds. Start-Point for DC Braking: 0.1-600Hz both when start up and stop.

13.0

Input Signal

13.1

Frequency Setting

13.1.1

Digital Operator Panel

By a rotary encoder (setting resolution 0.01Hz/step)

13.1.2

External Signal

0 ~ +10VDC((Input impedance 20k?), -10 ~ +10VDC((Input impedance 10k?),4 ~20mA dc ((Input impedance 250?),Multi-Function Inputs 1 ~ 6 (15 Steps Jog, up/down), PLC run, RS-485 Interface MODBUS protocol

13.2

Forward/Reverse/Start/Stop

13.2.1

Digital Operator Panel

Set by RUN, STOP and JOG

14.0

Other Functions

PID feedback control, automatic voltage regulation, Momentary Power Loss restart, S-Curve, External Fault, Fault Reset, Auto Restart, Fault Records, Prevention, Frequency Limits,Fan & Pump Control, Parameter Lock/Reset, Auto Tuning, Reverse Inhibition, Over-Voltage/ Over-Current Stall Prevention, automatic energy-saving, DC Braking, Speed Search during Start-up, PLC, MODBUS Communication,

15.0

Protective Function

Self-testing, AC source Over Voltage, Over Voltage, Over Current, Under Voltage, Over Load, Overheating, External Fault, Electronic thermal, Ground Fault, Stall Prevention, Output short circuit, IGBT short circuit

16.0

Environmental Conditions

16.1

Operating Temp.

Ambient: -10? ~ +40?(Non-Condensing and not frozen).Storage: -20? ~ +60?

16.2

Humidity

Below 90?RH (Non-Condensing)

16.3

Vibration

Below 20Hz: 1G, above 20Hz: 0.6G

16.4

Location

Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)

17.0

Mechanical Properties

17.1

Color

Black

17.2

Height

18.5 inches (470mm)

17.3

Width

16.1 inches (410mm)

17.4

Depth

11.3 inches (287mm)

17.5

Weight (lbs)

48.6

18.0

Options

Dynamic braking unit Braking resistor AC reactor

 
PC1-200 manufacturer: POLYSPEDE - USA
 
This product was added to our catalog on Thursday 18 September, 2008.
PC1-200
Quantity: 
PC1-200