SJ300-022LFU
[PSV4-30]
|
$565.00
|
|
 |
|
|
|
|
 |
|
1.0
|
Motor/Load Type
|
AC Motor
|
|
2.0
|
Rating
|
|
|
2.1
|
Horsepower
|
3
|
|
2.2
|
Motor
(kW)
|
2.2
|
|
2.3
|
Capacity
(kVA)
|
4.3
|
|
2.4
|
Output Current
(Amps)
|
10.5
|
|
3.0
|
Rated Input
|
|
|
3.1
|
Input Voltage
|
200 - 240VAC ±10%
|
|
3.2
|
Phase
|
3
|
|
3.3
|
Frequency
|
50/60 ±5%
|
|
4.0
|
Rated Output
|
|
|
4.1
|
Voltage
|
200 - 240VAC ±10%
|
|
4.2
|
Phase
|
3
|
|
4.3
|
Frequency
|
0.1 - 400 Hz
|
|
5.0
|
Control Method
|
Sine-wave (PWM) control
|
|
6.0
|
Frequency Range
|
0.1 - 1500 Hz optional (extra)
|
|
7.0
|
Frequency Accuracy
|
|
|
7.1
|
Digital Command
|
± 0.01% of the max. frequency
|
|
7.2
|
Analog Command
|
± 0.2% of the max. frequency
|
|
8.0
|
Frequency Setting Resolution
|
|
|
8.1
|
Digital
|
0.01 Hz
|
|
8.2
|
Analog
|
Max. frequency/4000
|
|
9.0
|
Volt./Freq. Characteristics
|
"V/F free setting, (30-400 Hz of base frequency), constant torque, and reduced torque of V/F control. Sensorless vector control"
|
|
10.0
|
Overload Current Rating
|
"150%, 60 Seconds 200%, 0.5 Seconds"
|
|
11.0
|
Acceleration/Deceleration Time
|
"0.1 - 3600 sec. (linear/curve, accel./decel. selection), Two stage accel./decel."
|
|
12.0
|
Starting Torque
|
"200% at 0.5 Hz (Sensorless vector control), 150% at around 0 Hz (Sersorless vector control, with a motor one size frame down)"
|
|
13.0
|
Braking
|
|
|
13.1
|
Dynamic Braking
|
Built-in BRD circuit Minimum value of resistor (ohms) - 35 ohms
|
|
13.2
|
DC Braking
|
"Performs at start; under set frequency at deceleration, or via an external input (braking force, time and operating frequency)"
|
|
14.0
|
Input Signal
|
|
|
14.1
|
Frequency Setting
|
|
|
14.1.1
|
Digital Operator Panel
|
Up(1) and Down(2) keys/value setting keys.
|
|
14.1.2
|
External Signal
|
"DC 0 ~ 10 VDC, -10V to +10V (input impedence 10k ohms), 4 ~ 20 mA (input impedence 100k ohms)"
|
|
14.1.3
|
External Port
|
Set by RS485
|
|
14.2
|
Forward/Reverse/Start/Stop
|
|
|
14.2.1
|
Digital Operator Panel
|
Run key/Stop key (FW/RV can be set by command)
|
|
14.2.2
|
External Signal
|
"FW RUN/STOP (NO contact), RV set by terminal assignment (NO/NC selection), 3-wire input possible"
|
|
14.2.3
|
External Port
|
Set by RS485
|
|
14.3
|
Intelligent Input Terminals
|
"Selection of 8 functions from: RV(Reverse), CF-ICF-4(Multispeed command),JG(Jogging),DB(ExternaI DC braking), SET(Second motor constants setting), 2CH(Secondaccel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), CS(Chan"
|
|
14.4
|
Thermistor Input
|
One terminal (PTC characteristics)
|
|
15.0
|
Output Signal
|
|
|
15.1
|
Intelligent Output Terminal
|
"Five open collector terminals and one NO-NC combined contact. Selection from: RUN(Run signal), FA(Frequency arrival signal (at the set frequency)), FA2(Frequency arrival (at or above the set frequency)), OL(Overload advance notice signal), OD(Output deviation for PID control), AL(Alarm signal), TRQ(In torque limit), RNT(Operation time over), ONT(Plug-in time over), THM(Thermal alarm), BRK(Brake release), BER(Brake error), ZS(Zero speed), Frequency arrival signal (at or above the set frequency)(2)), Frequency arrival signal (only at the set frequency)(2)), OL2(Overload advance notice signal)(2)), (Terminal 11-13 or 11-14 are automatically configured as ACO-AC2 or ACO-AC3 when alarm code output is selected at C62)"
|
|
16.0
|
Display Monitor
|
"Output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, input power, output voltage."
|
|
17.0
|
Other Functions
|
"V/F free setting (up to 5 points), frequency upper/lower limit, frequency jump, accel/decel curve selection, manual torque boost value and frequency adjustment, analog meter tuning, start frequency setting, carrier frequency setting, electronic thermal free-setting, external frequency output zero/span reference, external frequency input bias start/end, alalog input selection, retry after trip, restart after instantaneous power failure, various signal outputs, reduced voltage start, overload restriction, default value setting, deceleration and stop after power failure, AVR function, fuzzy accel/decel, auto-tuning (on-line/off-line), high torque multi operation."
|
|
18.0
|
Protective Function
|
"Over-current protection, overload protection, braking resistor overload protection, over-voltage protection, EEPROM error, under-voltage error, CT(Current transformer) error, CPU error, external trip USP error, ground fault, input over-voltage protection, instantaneous power failure, option 1 connection error, option 2 connection error, inverter thermal trip, phase failure detection, IGBT error, thermistor error"
|
|
19.0
|
Environmental Conditions
|
|
|
19.1
|
Operating Temp.
|
-10 ~ 50ºC
|
|
19.2
|
Storage Temp.
|
-20 ~ 65ºC
|
|
19.3
|
Humidity
|
20 ~ 90 % RH(no condensation)
|
|
19.4
|
Vibration
|
"5.9 m/s^2 (0.6G), 10 ~ 55 Hz"
|
|
19.5
|
Location
|
"Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)"
|
|
20.0
|
Mechanical Properties
|
|
|
20.1
|
Color
|
Gray
|
|
20.2
|
Height
|
10.0 inches (255 mm)
|
|
20.3
|
Width
|
5.9 inches (150 mm)
|
|
20.4
|
Depth
|
5.5 inches (140 mm)
|
|
20.5
|
Weight
(lbs)
|
7.7
|
|
21.0
|
Options
|
"Feedback PCB: Vector control with sensor Digital input PCB: 4-digit BCD, 16-bit binary EMI filters, Input/output reactors, DC reactors, Radio noise filters, Braking resistors, Braking units, LCR filters, Communication cables"
|
|
|
This product was added to our catalog on Monday 13 November, 2006.
|
 |
|
|
|